11/15/18KW Electric Swimming Pool Water Heater Thermostat Hot Tub Spa 220V. If an error occurs, the pool heater will stop immediately and a message will appear on the control panel so that the user or technician can determine where the error is. The safety of the customer is a top priority. Prohibit the use of seawater or salt-added disinfectants to sterilize thermostats(Excessive chlorine in disinfecting water is not good either, About 5 grams of water per cubic meter), as highly concentrated saltwater is very corrosive to stainless steel. Liner material: stainless steel Voltage: 220V Power: 11KW/15KW/18KW Phase: single phase Connection size: 40 mm (1.57) Machine size: 49 x 10 x 38 cm / L x W x H. Suitable for: hot tub & swimming pool equipment. The thermostat must work with a water pump with an appropriate capacity. If the pump and thermostat do not match, the flow rate is too low, the heating pipe is dry and can easily be damaged. 5.5KW-15KW heaters must operate with a pump with a water flow of at least 177 ft³ / hour (5m³/hour). 18KW-36KW heaters must operate with a pump with a water flow of at least 353 ft³ / hour (10m³/hour). 40KW-60KW heaters must operate with a pump with a water flow of at least 530 ft³ / hour (15m³/hour). The 1KW is suitable for 1 ft³? The 5.5KW thermostat is suitable for? 127 ft³ pool / 3.6m³? The 9KW thermostat is suitable for a pool with? 212 ft³ / 6m³? The 11KW thermostat is suitable for a pool with? 259 ft³ / 7.3m³? The 15KW thermostat is suitable for a pool of? 353 ft³ / 10m³? The 18KW thermostat is suitable for a pool with? 424 ft³ / 12m³. It is recommended to use the thermostat with a circulating water pump. Operating procedure: first turn on the water pump and then the thermostat. Shutdown: First turn off the thermostat, wait a while (10 seconds to 1 minute depending on the performance of the thermostat) and then turn off the pump. Reliable leak protection devices must be installed and commissioned by the responsible electrician. Monthly maintenance and inspection. The additional heating effect of the thermostat is better. Direct heating requires the use of a more powerful machine. 1 pool heater 1 English manual. ? Manual reset temperature switch? Prevent water from burning dry and protect the pool heater from overheating. ? Automatic shutdown in case of lack of water? The thermostat will not work if the pump does not start. It can effectively prevent water shortage and non-standard operation from damaging the machine. ? Temperature limit switch? It will turn off automatically when the temperature reaches the temperature, and it can automatically start the heating function after the temperature is lowered, which can effectively prevent damage from excessive machine temperature. ? Fuse protection? If the current is too large, the circuit breaker is immediately disconnected and the power supply interrupted. ? Power protection switch? Use the AC contactor as a start switch. Regardless of the type of accident, you can quickly disconnect the power supply and protect the safety of the machine and people. ? Smart self-diagnosis function? The control system continuesly monitors the operating status of all parts of the heater and reacts quickly and displays appropriate notification messages for each event to prevent from damage or malfunctions. We are not responsible for undeliverable address. X’mas or other reasons. Your patience is always appreciated. Dear friend: Welcome to me my services are available: Monday To Friday: 8:30 to 18:00 1. If it’s non-workdays, please kindly be patient and considerable to give us a little more time.
-
Recent Posts
- Resin Filled Swimming Pool LED Light 12V 55W RGB Remote Control Memory Function
- 2.5 HP Self Priming In/Above Ground Swimming Pool Pump 2 Speed 230V & Strainer
- 3/4 0.75 HP B625 Pool Booster Pump Replacement Motor For Polaris PB4-60
- For Hayward T-Cell-15 TurboCell Salt Chlorinator Cell 40,000 Gal Swimming Pool
- 3Y Warranty! Hayward GLX-PCB-PRO Pro-Logic NO CELL POWER FAST REPAIR SERVICE
Recent Comments
Archives
Categories
Meta
Calendar
November 2024 M T W T F S S « Oct 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Tag Cloud
15hp affordable automatic cartridge cell cleaner clear cord cover electric filter ground hayward heater in ground inground intex jandy krystal ladder light liner motor pack panel parts pentair pool pools pump replacement salt sand solar speed step strainer super superflo swimming system vacuum valve variable waterRecent Search Terms
- live5k2
- outlineo4n
- strangesu3
- Intex 1500 gpm filter pump with timer hoses included
- 633t pump parts
- pentair 011773 1 5 hp whisperflo wf-26
- Hydrofarm Active Aqua Submersible Water Pump 1000 GPH
- pentair wf 26 011773
- goplus products parts and service
- sf70110 pump parts
- krystal clear cs8110 replacement parts
- intex pools canada
- polygroup f1000c pool pump parts
- Operating Systems & Utilities – Tagged etl_processed_2016_04 – Page 16 – MyChoiceSoftware com
- everbilt pool cover pump
- polaris TR35P pool cleaner
- kokido replacement parts
- Armor Shield vs Gorilla Pad
- stingray pool cleaner reviews
- All – Tagged facebook_catalogue – Page 3 – MyChoiceSoftware com
Pages